Tankless Water Heater Not Heating?
Most no-heat calls come down to four things: too little flow to switch it on, too little gas to keep it lit, scale, or a blocked vent. Here is the order to check them in.
Shaheer Ali Khan
Consumer Product Testing & Materials Performance Specialist
Last Updated
October 17, 2026
In This Guide
A tankless water heater that stops heating is rarely broken in the expensive sense. It is a burner controlled by a flow sensor and a computer, and the computer shuts the burner down, or never lights it, whenever something upstream is wrong. Too little water flowing, too little gas arriving, too much scale on the heat exchanger, or a vent it cannot breathe through will each look like the same cold shower. Work through them in the order below, starting with the display, and most owners find the cause in under an hour without opening the cabinet. Anything involving gas pressure, burners or wiring inside the unit belongs to a licensed technician.
1. Five-Minute Triage: Read the Display and Narrow It Down
Start at the heater, not the faucet. Look at the controller or the display on the front of the unit. If it is blank, the heater has no power: check that it is plugged in, that the outlet works, and that the breaker or GFCI feeding it has not tripped. A gas tankless unit still needs 120 volts for its fan, igniter and control board, so a power cut or a tripped GFCI in a garage takes out the hot water just as surely as an empty gas line.
If the display shows a code, write it down before resetting anything. The code is the single most useful clue you have, and resetting the unit by switching the power off and on often clears it without fixing the cause. Look the code up in the owner's manual for your exact model, because the numbers are not standardized across brands. On Rinnai units, for example, code 10 points to an air supply or exhaust blockage, 11 to no ignition, 12 to flame failure, 14 to an overheat condition and LC to scale buildup. Navien uses its own E-codes, such as E003 for ignition failure and E012 for flame loss.
Next, establish the pattern, because the pattern points to the cause. Is it every hot tap in the house or only one? Does it fail all the time, or only when two fixtures run together, or only when the furnace is also running? Does hot water arrive and then turn cold mid-shower? Is it worse in winter? A single fixture means the problem is almost certainly at that fixture. A whole-house failure with a code points at the heater, its gas or its vent.
| What you see | Most likely cause | Check first |
|---|---|---|
| Blank display, no hot water anywhere | No power to the unit | Plug, outlet, GFCI, breaker |
| Ignition or flame failure code | Gas supply or gas line too small | Gas valve open, other gas appliances, propane level |
| Hot at the kitchen, cold at a low-flow tap | Flow below activation rate | Aerator, showerhead, mixing valve setting |
| Hot, then cold during a shower with others running | Gas line too small or demand above unit capacity | Turn off other fixtures and appliances, retest |
| Temperature swings and a scale code | Scale in the heat exchanger | Descale the unit |
| Air or exhaust code, worse in snow or wind | Blocked vent or intake | Vent terminations outside |
| Hot water lukewarm everywhere, no code | Crossover or setpoint | Crossover test, controller setting |
Finally, check the obvious settings. Make sure the temperature setpoint on the controller has not been turned down, that a second controller in a bathroom is not set lower and in charge, and that the isolation valves under the unit are fully open after any recent service. A surprising number of no-heat problems appear the morning after someone flushed the heater and left a valve half closed.
2. Minimum Flow Rate: When the Heater Never Switches On
A tankless heater does not fire until its flow sensor sees enough water moving through it. That threshold is the minimum activation flow rate, and once lit, the unit stays on down to a slightly lower minimum flow rate. Rinnai and Rheem condensing models are commonly specified at about 0.4 gallons per minute to activate and about 0.26 to keep running. Navien's NPE-A2 series lists 0.5 GPM to activate, with an optional setting that allows much lower flow. Below those numbers, water simply passes through cold.
That is why one tap can be cold while others are fine. A bathroom faucet with a 0.5 GPM aerator barely meets the threshold, and opened halfway it does not. A single-handle faucet turned only partly toward hot sends a trickle of hot through the heater and the rest of the flow from the cold line. A low-flow showerhead with the mixing valve set warm rather than hot can draw less hot water than the activation rate. Open the tap fully to hot and see if the heater lights. If it does, the heater is fine and the fixture is the issue.
Restrictions upstream lower flow too. Most tankless units have an inlet water filter screen on the cold connection, which catches sediment and scale flakes and slowly clogs. Fixture aerators and showerheads clog with the same debris, especially after plumbing work or a water main repair. Unscrew the aerator on the problem tap and run it; if flow improves and the heater fires, clean or replace the aerator. Then shut off the isolation valves, drain the unit and clean the inlet screen as described in the owner's manual.
If low-flow fixtures are important to you, two fixes exist. Some units allow the activation threshold to be lowered or offer a small buffer tank accessory, and many have recirculation options that keep water moving. The other fix is fixture choice: a 0.5 GPM lavatory aerator and a tankless heater are a poor match. Our tankless sizing guide covers flow rates by fixture, and the best tankless water heaters guide notes which models handle low flows well.
3. Gas Supply and Undersized Gas Lines
A whole-house gas tankless heater can draw up to about 199,000 BTU an hour at full fire, several times what a typical tank heater uses. If the gas line, meter or propane regulator cannot deliver that while the furnace, range and dryer are also running, the pressure at the heater sags, the flame becomes unstable, and the unit shuts down with an ignition or flame failure code. The giveaway is a heater that works on a single shower in summer and fails in winter, or whenever a second fixture opens.
Start with the simple checks. Confirm the gas valve on the line to the heater is fully open. Check that other gas appliances in the house are working; if the range will not light either, the problem is the supply, not the heater. With propane, check the tank gauge, because a tank under about 20 percent may not deliver enough pressure in cold weather, and a regulator that ices up can starve the heater on a cold morning. If the heater was recently installed and has never been reliable, suspect the gas line size first.
Gas pressure has to be right while everything is running, not just at rest. Rinnai, for instance, specifies a flowing inlet pressure of 4 to 10.5 inches of water column on natural gas and 8 to 13.5 inches on propane, measured with all gas appliances firing at their maximum rate. Measuring that requires a manometer on the heater's test port, and it is a job for a licensed gas fitter or the installer, not a homeowner. If the reading drops below the minimum under load, the line or meter is undersized.
The fix for an undersized line is a larger line, commonly 3/4 inch to the heater, and sometimes a meter upgrade from the gas utility. That is an installation defect, so call the original installer first. In the meantime, you can reduce symptoms by not running the dryer, furnace and two showers at once. Our tankless water heater cost guide covers what gas line upgrades typically run if you are paying for it.
4. Scale: The Slow Cause That Ends in No Heat
In hard water, calcium and magnesium carbonate precipitate out of the water as it heats and coat the inside of the heat exchanger. The coating insulates the water from the burner, so the heat exchanger runs hotter for the same output and the unit struggles to hold its setpoint. Early signs are temperature swings and slightly lower maximum flow. Later the unit trips on an overheat sensor or displays a scale warning, and eventually it stops heating reliably at all.
Many units detect this before you notice. Rinnai uses the LC code for scale buildup, and it is one of the few codes that lets the heater keep running while it alternates with the temperature display, which is the heater asking to be flushed. Other brands use their own codes and may lock the unit out until it is serviced. Do not keep resetting a scale warning; each reset buys a little time while the deposit thickens.
The fix is descaling: isolating the heater with its service valves and circulating a descaling solution or white vinegar through it with a small pump for about an hour, then flushing with fresh water. Our step-by-step guide on how to flush a tankless water heater covers the pump, the hoses and how often your water hardness calls for it. If the unit heats properly afterward, scale was the cause, and the question becomes how to keep it from coming back.
Prevention depends on hardness. Rinnai's published water-quality limit puts total hardness at up to about 200 mg/L, roughly 12 grains per gallon, and manufacturers generally exclude scale damage from heat exchanger warranty coverage. If you are flushing more than once a year, a whole-house softener or a scale-reduction system upstream of the heater is cheaper than an early heat exchanger replacement. Our best water softener systems guide covers the options.
5. Venting and Combustion Air
A gas tankless heater needs to pull in combustion air and push out exhaust through its vent, and its fan and pressure sensors watch both. If the intake or exhaust is blocked, the heater will refuse to light or shut down mid-run with an air supply or exhaust code. On Rinnai units that is code 10; other brands have their own equivalents. Because the vent is outside, these failures often line up with weather: a snowdrift over a sidewall termination, ice in a vent cap, leaves blown into an intake, or a wasp nest in a summer-idle outdoor unit.
Check the terminations outside first. Look for snow, ice, leaves, insect nests, plastic bags or anything stacked against the wall. Make sure nothing new has been built in front of the vent, such as a deck, a shed or a privacy screen, and that a dryer vent or another appliance exhaust is not blowing into the heater's intake. Clear what you can reach safely. If the vent is on the roof, or the code returns once the termination is clear, call a technician to inspect the vent run itself.
Condensing units add a second airflow-related cause: condensate that cannot drain backs up into the unit and trips a safety switch. Rinnai's diagnostic manual describes a dedicated code for condensate backing up into the trap. Check that the condensate line is not kinked, frozen, blocked with debris, or draining into a condensate pump that has failed, and that a neutralizer cartridge is not clogged. Our condensing vs non-condensing comparison explains why that drain exists and how to keep it from freezing.
SAFETY
Never run a gas heater with a damaged vent.
A cracked, disconnected or improperly joined vent can leak carbon monoxide into the house. If you see a separated joint, scorching, soot around the unit or the vent, or your CO alarm sounds, turn the heater off at its gas valve and call a licensed technician. Make sure there is a working CO alarm near any fuel-burning appliance.
Two less common causes are worth knowing. High-altitude installations need the correct altitude setting or the burner runs out of balance and can trip flame or air codes. And a unit installed in a cramped closet without enough makeup air, or in a space with chemical fumes from laundry products or pool supplies, can struggle for clean combustion air. Both are installer issues rather than owner fixes.
6. The Cold-Water Sandwich vs a Plumbing Crossover
Two problems are often confused with a heater that is not heating. The first is the cold-water sandwich: you shower, turn the water off briefly, turn it back on and get a few seconds of hot water, then a slug of cold, then hot again. It happens because the hot water left in the pipe comes out first, followed by water that passed through the heater during the few seconds it took to relight. It is normal tankless behavior, it lasts seconds, and a recirculation system or a unit with a small built-in buffer reduces it.
The second is a plumbing crossover, and it is a real fault. A crossover happens when cold water leaks into the hot line somewhere in the house, usually through a failed cartridge in a single-handle faucet, a worn pressure-balancing or thermostatic shower valve, a mixing valve at a utility sink, or a thermostatic bypass valve used for recirculation. The result is lukewarm water at every tap, or a heater that will not fire at a fixture because cold water from the crossover is filling the flow the heater should be seeing.
The crossover test is simple. Close the cold-water inlet valve on the heater, then open a hot tap somewhere in the house. With the heater's supply shut off, nothing should flow from a hot tap except a brief drain-down of the pipe. If water keeps running steadily, cold water is getting into the hot side somewhere. Then turn off fixtures or close their stop valves one at a time until the flow stops; the last one you closed is the culprit, and a new cartridge or valve usually fixes it.
Tankless systems are more sensitive to crossovers than tank systems for a simple reason. A tank heater will push hot water into the line regardless, and the crossover just dilutes it. A tankless heater depends on seeing enough flow through itself to fire, and a crossover can divert part of that flow around the heater entirely. If you have a crossover recirculation valve under a sink, as many tankless setups do, it is the first fixture to suspect.
7. Electric Tankless Units, and When to Call a Pro
Electric tankless heaters fail differently, because there is no gas, flame or vent. Whole-house electric units use several heating elements, each usually fed by its own double-pole breaker. A large 27 kW unit typically needs three 40-amp double-pole breakers. If one of them trips, the heater still runs but delivers lukewarm water, because it has lost a third of its power. Check every breaker serving the unit before assuming anything inside it has failed, and if one keeps tripping, stop resetting it and call an electrician.
Elements can burn out, and the most common reason is dry firing: the unit is powered while there is air rather than water around the elements, typically after plumbing work or a flush when the lines were not purged. Always run hot water through a fixture until it flows steadily, with no sputtering, before restoring power after any work. A burned-out element shows as one stage that never heats, and on many units elements are replaceable, but it is an electrical repair inside a high-amperage appliance.
The other electric limitation is physics, not failure. Heating water takes a fixed amount of energy, so a unit that comfortably heated 3 GPM of 65-degree summer water may only manage half that in January when the inlet is 40 degrees. If the water is lukewarm only in winter and only at higher flows, the heater is working at its limit. That is a sizing issue, covered in our tankless sizing guide, and the options are lower-flow fixtures, a second unit or a gas model.
When to Stop and Call a Professional
Call a licensed technician for anything involving gas pressure, gas line size, burner, igniter, flame rod, fan, circuit board or internal wiring; for any vent damage or carbon monoxide alarm; for a code that returns after you have cleared the obvious causes; for water leaking from the cabinet or the condensate line when the unit is not running, which can indicate a leaking heat exchanger; and for any repair on a unit still under warranty, because unauthorized repairs can void coverage. If the heater is old and these failures are starting to pile up, our guide to how long tankless water heaters last covers when repair stops making sense.
8. Common Mistakes to Avoid
Resetting Without Reading the Code
Switching the heater off and on often clears the display without fixing anything. Write the code down first and look it up in the manual for your model, because codes differ by brand. A code that keeps returning is the heater telling you exactly where to look, and it is what a technician will ask for.
Blaming the Heater for One Cold Tap
If the kitchen runs hot and one bathroom sink does not, the heater works. That tap is either flowing below the activation rate, clogged at the aerator, or has a failed cartridge causing a crossover. Open it fully to hot, clean the aerator, and run the crossover test before calling for heater service.
Ignoring a Scale Warning
A scale code is an early warning, not a fault, and some units keep running while they display it. Resetting it repeatedly lets the deposit thicken until the heat exchanger overheats or cracks, and scale damage is excluded from manufacturers' warranties. Descale as soon as the code appears and test your water hardness.
Leaving Valves Half Closed After a Flush
After descaling, the service valves must be returned fully to their operating positions and the inlet screen refitted. A half-closed isolation valve restricts flow enough to stop the heater lighting at low-flow fixtures. If problems started right after maintenance, check every valve on the unit before looking anywhere else.
Powering an Electric Unit Before Purging Air
Restoring power to an electric tankless heater while its lines hold air can burn out an element in seconds. After any plumbing work or flush, open a hot tap and let water run steadily with no sputtering before switching the breakers back on. A dry-fired element is an avoidable repair.
9. Frequently Asked Questions
Why is my tankless water heater not heating?
The most common causes, in order, are flow too low to activate the heater, an inadequate gas supply or undersized gas line, scale in the heat exchanger, and a blocked vent or intake. Check the display for an error code first, then whether the problem affects one tap or all of them, and whether it only happens when other appliances run.
Why does my tankless water heater have no hot water at one faucet only?
A single cold faucet almost always means a fixture problem. The flow at that tap may be below the heater's activation rate, often around 0.4 to 0.5 GPM, because of a low-flow aerator, a clogged screen or a mixing handle not turned fully to hot. A failed faucet cartridge can also cause a crossover that lets cold water into the hot line.
Why does my tankless water heater go hot then cold?
A few seconds of cold between hot is the normal cold-water sandwich. Longer cold spells mid-shower usually mean demand exceeded the heater's capacity, the gas supply sagged when another appliance started, or flow dropped below the minimum. If it happens with only one fixture running, suspect gas pressure, scale or a dirty inlet filter.
How do I reset a tankless water heater?
Most units reset by switching off the power to the heater for about a minute and back on, or by pressing the on and off button on the controller. Write the error code down before resetting, because resetting can clear the code without fixing the cause. If the same code returns, find the cause or call a technician rather than resetting repeatedly.
Can low gas pressure stop a tankless water heater from heating?
Yes. Whole-house units can draw up to about 199,000 BTU an hour, and if the gas line, meter or propane regulator cannot keep pressure up while other appliances run, the heater shows an ignition or flame failure code. Rinnai, for example, specifies 4 to 10.5 inches of water column on natural gas under full load. A licensed gas fitter should measure it.
How do I know if my tankless water heater has a crossover?
Shut the cold-water inlet valve on the heater, then open a hot tap in the house. If water keeps flowing steadily after the pipe drains down, cold water is entering the hot line somewhere. Close fixture stop valves one at a time until the flow stops. Failed single-handle faucet cartridges and shower valves are the usual culprits.
Why is my electric tankless water heater lukewarm?
Check every breaker that feeds it first, because whole-house electric units often use two or three double-pole breakers and losing one cuts output sharply. A burned-out element, often from powering the unit before purging air, does the same. If it is lukewarm only in winter at high flow, the unit is at its capacity limit, which is a sizing issue.
Related Tankless Water Heater Guides
Buyer's Guide
Best Tankless Water Heaters
The units we recommend, ranked on real flow at winter groundwater temperatures.
Maintenance
How to Flush a Tankless Water Heater
The pump-and-bucket descale that fixes scale codes and temperature swings.
Comparison
Condensing vs Non-Condensing Tankless
Efficiency, venting, condensate drains and which costs less installed.
The Bottom Line
When a tankless water heater stops heating, read the code, then check in order: power and settings, flow at the fixture, gas supply, scale, and the vent and condensate drain. Run the crossover test if the water is lukewarm everywhere, and check every breaker on an electric unit. Most causes are found without opening the cabinet.
Leave gas pressure, burners, boards and wiring to a licensed technician, and call one immediately for any vent damage or CO alarm. If scale was the cause, test your water hardness and descale on a schedule, because the next failure from scale is the one that ends the heat exchanger.